Detailed information

搜索历史清除全部记录
最多显示8条历史搜索记录噢~
All
  • All
  • Product Management
  • News and Information
  • Introduction content
  • Business outlets
  • Frequently Asked Questions
  • Corporate Video
  • Corporate Portfolio

Image Name
+
  • CS系列xg.jpg

CS Series

Product features and applications:

• Solid, liquid, and slurry samples can all be detected, unaffected by viscous media.
• 3 switching points + continuous detection, with a maximum range of 3,000 mm, and analog output (4–20 mA, 0–1 V)
• Operating temperature range: 0–70°C, container pressure: ≤10 bar
• IP67-rated protection, with M12 connector or cable output

Category:

Continuous Level Sensor

Keywords:

FINEHOOD

Sensor

Retail price

Yuan

Market price

Yuan

  • Product Details
  • Product Dimensions
  • Product Selection
  • Wiring Diagram
    • Commodity name: CS Series
    • 产品特点及应用: • Solid, liquid, and slurry samples can all be detected, unaffected by viscous media. <br/> • 3 switching points + continuous detection, with a maximum range of 3,000 mm, and analog output (4–20 mA, 0–1 V) <br/> • Operating temperature range: 0–70°C, container pressure: ≤10 bar <br/> • IP67-rated protection, with M12 connector or cable output

    • Detects solids, liquids, and slurries—unaffected by viscous media • Features 3 switch points plus continuous monitoring, with a maximum range of 3,000 mm and analog output options (4–20 mA, 0–1 V)

    Analog Level Sensor Technical Data Sheet
    Product Line FH-CS-1 Road PNP Output + 1 Channel Analog Output   Product Line FH-CS-3 Road PNP Output + 3 Analog Output Channels   Product Line FH-CS-4 (4-channel PNP output)
    Operating Voltage 20-30VDC Operating Voltage 20-30VDC Operating Voltage 20-30VDC
    Operating current <80mA Operating current <80mA Operating current <80mA
    Analog Output (Short-Circuit Protection / Reverse Polarity Protection) There is Analog Output (Short-Circuit Protection, Reverse Polarity Protection) There is Analog Output (Short-Circuit Protection, Reverse Polarity Protection) None
    0-10V output Load minimum 500Ω 0-10V output Load minimum 500Ω 0-10V output None
    0-20mA output Load maximum 500Ω 0-20mA output Load maximum 500Ω 0-20mA output None
    4-20mA output Load maximum 500Ω 4-20mA output Load maximum 500Ω 4-20mA output None
    Digital Output P NP (NO/NC Switchable) Digital Output P NP (NO/NC Switchable) Digital Output P NP (NO/NC Switchable)
    Load current Up to 200mA (with short-circuit protection) Load current 3 channels, maximum 200mA (with short-circuit protection) Load current Up to 200mA (with short-circuit protection)
    Switch Point Setting 5–95% adjustable Switch Point Setting 5–95% adjustable Switch Point Setting 5–95% adjustable
    Measurement accuracy ±3% of the maximum measurement range Measurement accuracy ±3% of the maximum measurement range Measurement accuracy ±3% of the maximum measurement range
    Repeatability precision ±1% of the maximum measurement range Repeatability precision ±1% of the maximum measurement range Repeatability precision ±1% of the maximum measurement range
    Protection Level IP67 Protection Level IP67 Protection Level IP67
    Operating temperature range 0–60°C Operating temperature range 0–60°C Operating temperature range 0–60°C
    Medium temperature range 0–70°C Medium temperature range 0–70°C Medium temperature range 0–70°C
    Storage Temperature Range -25 to +80°C Storage Temperature Range -25 to +80°C Storage Temperature Range -25 to +80°C
    Maximum medium pressure 0.3MPa Maximum medium pressure 0.3MPa Maximum medium pressure 0.3MPa
    Dielectric constant of the medium >1.8 Dielectric constant of the medium >1.8 Dielectric constant of the medium >1.8
    Ambient temperature 0…+60℃ Ambient temperature 0...+60°C Ambient temperature 0… +60℃
    Maximum Capacitance Measurement Range 0 to 3.3 nF Maximum Capacitance Measurement Range 0 to 3.3 nF Maximum Capacitance Measurement Range 0 to 3.3 nF
    Electrical interface M12 Connector Electrical interface M12 Connector Electrical interface M12 Connector
  •  

     

     

  • Analog Level Sensor Encoding Rules

     

    Series Probe rod outer shell material Probe rod length Output Thread Specifications Other notes
    Example: FH-CST025EA1G1
    FH-CS T 025  EA1 G1 Default M12 connector,

    Line Manager

    Customizable
     
      E-PEEK 020-200mm EA1 - Analog Output 4-20mA + 1 Digital Input G1-G1"
      T-PTFE 025-250mm EA3 - Analog Output 4-20mA + 3-Point Digital Inputs G2-G1-1/2"
        050-500mm EV1 - Analog Output 0-10V + 1 Digital Input/Output G4-G1-1/4"
        100-1000mm EV3 - Analog Output 0-10V + 3-Point Digital Inputs  
        200-2000mm EC4-4-point Digital Input/Output  
        300-3000mm ……  

    Note: 1. The PEEK body has a maximum length of 300 mm. 2. The probe rod starts at 200 mm in length, with custom lengths available in increments of 50 mm.

CS Series

Product features and applications:

• Solid, liquid, and slurry samples can all be detected, unaffected by viscous media.
• 3 switching points + continuous detection, with a maximum range of 3,000 mm, and analog output (4–20 mA, 0–1 V)
• Operating temperature range: 0–70°C, container pressure: ≤10 bar
• IP67-rated protection, with M12 connector or cable output

Category:

Continuous Level Sensor

Keywords:

FINEHOOD

Sensor

Retail price

Yuan

Market price

Yuan

Online Quotation Request


We will contact you with in one working day. Please pay attention to your email.

Submit

Frequently Asked Questions


What are the regular maintenance tasks for the website?


Regular website maintenance is key to ensuring the site remains secure, operates smoothly, and delivers a great user experience. Maintenance tasks include updating website content, checking and fixing broken links, backing up data, conducting routine security audits, patching vulnerabilities, and optimizing performance. These efforts help keep the website running efficiently over the long term while providing users with a seamless and enjoyable experience.

What’s the difference between UI and UX in website design?


UI (User Interface) and UX (User Experience) are two crucial aspects of website design. While UI focuses on the visual design, layout, and elements of a website, UX emphasizes the overall feeling and interaction users have when navigating the site—covering factors like usability, navigation, and interactivity. Exceptional UI design typically enhances the user’s UX experience.

What types of web hosting services are available?


Website hosting services can be categorized into shared hosting, virtual private servers (VPS), dedicated servers, and cloud hosting. Shared hosting involves multiple websites sharing the resources of a single server, while VPS offers a virtualized environment that mimics a dedicated server. Dedicated servers provide an exclusive, standalone setup for a single website, and cloud hosting delivers hosting solutions through cloud-based services. Each type comes with its own unique features and is suited to different use cases.

What is the purpose of a website traffic statistics tool?


Traffic analytics tools like Google Analytics help analyze website visit data, including visitor sources, page views, and user behavior. By gaining insights from this data, website owners can better understand their audience, refine website content and design, enhance the user experience, and ultimately boost conversion rates.

How to choose the right website-building technology for yourself?


Choosing website-building technology depends on your personal technical skills and the specific needs of your site. If you’re familiar with programming, you can opt to write your own code using HTML, CSS, JavaScript, and other tools. Alternatively, you might consider leveraging existing frameworks or libraries, such as Bootstrap or React, to streamline the development process.

How to start building your own website?


To build a website, you first need to choose a domain name, which serves as the website’s address. Next, select a reliable hosting provider, as this is where your website files and data will be stored. After that, either write the website’s code or design its pages—whichever approach suits your needs. Finally, upload the website files to the server. And just like that, your site will be ready to be accessed and browsed online!