Image Name
+
  • LPPS侧装系列.jpg

LPPS Side-Mount Series

Product features and applications:

• Passive sensing magnetic dual-element design to prevent equipment damage
• The float rises and falls with the liquid level, triggering the switch to turn on or off.
• Side-mount and inverted installation available, ensuring reliable performance
• PVDF corrosion-resistant material, specially designed for acidic and alkaline corrosive solutions
• Temperature range: -20 to 85°C
• Default cable length is 2m, with maximum contact impedance not exceeding 1Ω

Category:

PVDF Float Switch

Keywords:

FINEHOOD

Sensor

Retail price

Yuan

Market price

Yuan

  • Product Details
  • Product Dimensions
  • Product Selection
  • Wiring Diagram
    • Commodity name: LPPS Side-Mount Series
    • 产品特点及应用: • Passive sensing magnetic dual-element design to prevent equipment damage <br/> • The float rises and falls with the liquid level, triggering the switch to turn on or off. <br/> • Side-mount and inverted installation available, ensuring reliable performance <br/> • PVDF corrosion-resistant material, specially designed for acidic and alkaline corrosive solutions <br/> • Temperature range: -20 to 85°C <br/> • Default cable length is 2m, with maximum contact impedance not exceeding 1Ω

    • Passive inductive dual-element design to prevent equipment damage • The float rises and falls with the liquid level, triggering the switch to turn on and off

    PVDF Reed-Type Float Switch Technical Data Sheet 1
    1. Shape, Dimensions, and Wiring Components: Mostly custom-made; please refer to the [Outline Dimension Drawing] for the specific model.
    2. Contact type: Type A contact
    3. Usage specifications:
    3 - 1. Maximum contact power: 10 W
    3 - 2. Maximum Operating Voltage: DC or AC voltage up to 200V
    3 - 3. Maximum Operating Current: 0.5A DC or AC
    3 - 4. Operating temperature range: -30°C to 100°C
    3 - 5. Standard liquid to use: Water
    3 - 6. Operating ambient humidity: Maximum RH 95% (40°C)
    4. Product Performance:
    4 - 1. Action Type: Normally Open or Normally Closed
    4 - 2. Contact Impedance: (Set line length within 1 meter) Maximum resistance value not exceeding 400 mΩ
    4 - 3. Insulation resistance between terminal and housing: Minimum resistance value of 108 Ω (DC voltage 500V)
    4 - 4. Insulation Withstand Voltage Between Terminals: DC Voltage of 150V or Higher (with current cut-off at 1mA, for 1 minute)
    4–5. Insulation withstand voltage between terminals and housing: 1500V DC, 2000V AC (with current cut-off at 1 mA, for 1 minute)
    4–6. Electrical Life: Over 1 x 10^6 cycles (DC 5V, 5mA)
    4–7. Impact Resistance: No malfunction under impacts of 30G or less
    4–8. Vibration Resistance: The device was subjected to 2-hour vibrations in the X, Y, and Z directions, with a frequency range of 10–55 Hz and an amplitude of 1.52 mm, showing no abnormalities.

     

    PVDF Reed-Type Float Switch Technical Data Sheet 2
    1. Shape and Dimensions: Mostly custom-made; please refer to the [Overall Dimension Drawing] for the specific model.
    2. Contact type: Type A contact
    3. Usage specifications:
    3 - 1. Maximum contact power: 50W
    3 - 2. Maximum Operating Voltage: DC or AC voltage 250V
    3 - 3. Maximum Operating Current: 1A DC or AC
    3 - 4. Operating temperature range: -30°C to 100°C
    3 - 5. Standard liquid to use: Water
    3 - 6. Operating ambient humidity: Maximum RH 95% (40°C)
    4. Product Performance:
    4 - 1. Action Type: Normally Open or Normally Closed
    4 - 2. Contact Impedance: (Set line length within 1 meter) Maximum resistance value not exceeding 400 mΩ
    4 - 3. Insulation resistance between the terminal and the housing: Minimum resistance value of 108Ω (DC voltage 500V)
    4 - 4. Insulation Withstand Voltage Between Terminals: DC Voltage of 150V or Higher (with current cut-off at 1mA, for 1 minute)
    4–5. Insulation withstand voltage between terminals and housing: 1500V DC, 2000V AC (with current cut-off at 1 mA, for 1 minute)
    4 - 6. Electrical life: 1 x 10 6 Number of times or more (DC 5V, 5mA)
    4–7. Impact Resistance: No malfunction under impacts of 30G or less
    4–8. Vibration Resistance: The device was subjected to 2-hour vibrations in the X, Y, and Z directions, with a frequency range of 10–55 Hz and an amplitude of 1.52 mm—no abnormalities were observed.
  •  

     

  •  

     

    PVDF level sensor coding rules:

     

  •  

     

LPPS Side-Mount Series

Product features and applications:

• Passive sensing magnetic dual-element design to prevent equipment damage
• The float rises and falls with the liquid level, triggering the switch to turn on or off.
• Side-mount and inverted installation available, ensuring reliable performance
• PVDF corrosion-resistant material, specially designed for acidic and alkaline corrosive solutions
• Temperature range: -20 to 85°C
• Default cable length is 2m, with maximum contact impedance not exceeding 1Ω

Category:

PVDF Float Switch

Keywords:

FINEHOOD

Sensor

Retail price

Yuan

Market price

Yuan

Online Quotation Request


We will contact you with in one working day. Please pay attention to your email.

Submit

Frequently Asked Questions


What are the regular maintenance tasks for the website?


Regular website maintenance is key to ensuring the site remains secure, operates smoothly, and delivers a great user experience. Maintenance tasks include updating website content, checking and fixing broken links, backing up data, conducting routine security audits, patching vulnerabilities, and optimizing performance. These efforts help keep the website running efficiently over the long term while providing users with a seamless and enjoyable experience.

What’s the difference between UI and UX in website design?


UI (User Interface) and UX (User Experience) are two crucial aspects of website design. While UI focuses on the visual design, layout, and elements of a website, UX emphasizes the overall feeling and interaction users have when navigating the site—covering factors like usability, navigation, and interactivity. Exceptional UI design typically enhances the user’s UX experience.

What types of web hosting services are available?


Website hosting services can be categorized into shared hosting, virtual private servers (VPS), dedicated servers, and cloud hosting. Shared hosting involves multiple websites sharing the resources of a single server, while VPS offers a virtualized environment that mimics a dedicated server. Dedicated servers provide an exclusive, standalone setup for a single website, and cloud hosting delivers hosting solutions through cloud-based services. Each type comes with its own unique features and is suited to different use cases.

What is the purpose of a website traffic statistics tool?


Traffic analytics tools like Google Analytics help analyze website visit data, including visitor sources, page views, and user behavior. By gaining insights from this data, website owners can better understand their audience, refine website content and design, enhance the user experience, and ultimately boost conversion rates.

How to choose the right website-building technology for yourself?


Choosing website-building technology depends on your personal technical skills and the specific needs of your site. If you’re familiar with programming, you can opt to write your own code using HTML, CSS, JavaScript, and other tools. Alternatively, you might consider leveraging existing frameworks or libraries, such as Bootstrap or React, to streamline the development process.

How to start building your own website?


To build a website, you first need to choose a domain name, which serves as the website’s address. Next, select a reliable hosting provider, as this is where your website files and data will be stored. After that, either write the website’s code or design its pages—whichever approach suits your needs. Finally, upload the website files to the server. And just like that, your site will be ready to be accessed and browsed online!